Problem

The value of LFW was 0, although fission widths were given for URR. The resonance parameters were inconsistent between MF2 and MF32. The problem was informed by Dr. C. Mattoon (LLNL) on the 12th of April, 2013.

Action

The LFW value was changed to 1 for MF2/MT151 and MF32/MT151. The parameters for the -0.97 eV resonance in MF32/MT151 were corrected so that they were consistent with those in MF2/MT151. The covariance data remain unchanged. These modifications were done by O. Iwamoto.

u234

u234

u234

u234